2.2 Wiring
When conduct wiring, follow the instructions below.
 
Use shield wire for control signal line and ground the unit with shield wire.
 
Applicable wire size for TB1 is 0.2 to 2.5mm
2
.
 For TB2, it is 0.2 to 1.5mm
2
.
 
Peel off the end of the wire by about 5mm (7mm for TB1).
 
For connecting wires, use screwdriver that has a blade tip of 0.4mm thickness and 2.5mm width.
 (For TB3, thickness and width should be 0.6mm and 3.5mm.)
 
Tightening torque of the terminal block should be 0.22 to 0.25N
m .
 (For TB1, it is 0.5 to 0.6N
m.)
 
Never bind the signal line and main circuit connection wire together.
 Separate the signal line and the main circuit connection wire by more than 200mm.
 
Use 0.75mm
2
 wire for the connection of PGCC terminal of the option side and CC terminal of the inverter.
 
Use 0.75mm
2
 wire for the connection of grounding terminal of the option side and that of the inverter.
„
  < PG interface > [ TB2 terminal]
Terminal
name
Function
Specification
Internal circuit
PGA1
PGA2
PG feedback input,
Pulse row speed
command input
(Phase A input)
PGB1
PGB2
PG feedback input
Pulse row speed
command input
(Phase B input)
PGZ1
PGZ2
PG feedback input
Pulse row speed
command input
(Phase Z input)
 PG feedback
 
15V complementary / open
collector
 
12V complementary / open
collector
 
Maximum input frequency
 60kpps (2 phases)
 120kpps (single phase)
 
Pulse duty
 50  ± 10%
4 7 0 Ω
4 7 0 Ω
PGA1
PGB1
PGZ1
PGA2
PGB2
PGZ2
Photocoupler
:1.2~1.7V
PGVC
PGCC
PG power supply terminal  12VDC
160mA or less