5700 Step Top Wood Stove Series ACC
F. Masonry Chimney Liner
Thimble Assembly:
12 in. (305mm) of 
brick separation 
between clay liner 
and combustibles.
Fireclay liner 5/8 in. 
(16mm) Minimum 
or Equivalent.
Sill support
Header
Wood Stud 2 in. 
(51mm) 
Clearance from 
chimney wall
Fireclay liner 5/8 in.  
(16mm) Minimum 
or Equivalent.
Figure 37.1
For  optimal  performance,  masonry  chimneys  used  to  vent 
this appliance should be:
1. Lined with a 6 inch (152mm) stainless steel liner.  
 
•  Installations into a clay fl ue without a stainless steel 
liner  may  reduce  draw  which  affects  performance, 
cause  the  glass  to  darken  and  produce  excessive 
creosote. 
2. It is recommended that a chimney with a larger diameter 
than 6 inches (152mm) be relined. 
 
•  The oversized fl ue can cause poor performance and 
contribute to the accumulation of creosote.  
3.  Have the chimney cleaned before the stove is installed 
and operated. 
The following bullets list the more critical requirements for a 
properly constructed chimney: 
• 
The  masonry  wall  of  the  chimney,  if  brick  or  modular 
block, must be a minimum of 4 inches (102mm) nominal 
thickness.
• 
A  chimney  of  rubble  stone  must  be  at  least  12  inches 
(305mm) thick.
• 
The chimney must have a fi re clay fl ue liner (or equivalent) 
with a minimum thickness of 5/8 inch (16mm) and must 
be installed with refractory mortar.
• 
An equivalent liner must be a listed chimney liner system 
or other approved material.
Since an oversized fl ue contributes to the accumulation 
of  creosote,  the  size  of  the  fl ue  should  be  checked  to 
determine that it is not too large for the insert.
The chimney should also be checked to ensure it meets 
the  minimum  standard  of  the  National  Fire  Protection 
Association (NFPA) Standard 211.
•  A  chimney  support  package  must  be  used  when  a 
connection is made through the ceiling to a factory built 
chimney.
•  An approved thimble and chimney support package are 
absolutely  necessary  to  provide  safe  clearances  to 
combustible wall and
 
ceiling material.
NOTICE:  In Canada, the installation shall conform to 
CAN/CSA-B365.  
NOTICE:  Check  with  your  local  building  authorities 
and/or consult the National Fire Protection Association 
(NFPA 211).