  Tissue Loading Bar Graph at the segment Set Point selected.
  NORM/GAUG Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18
M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
  Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
  Entry into Decompression Mode (Deco).
  Conditional Violation (above a required Deco Stop Depth for less than 5 minutes).
  Delayed Violation (above a required Deco Stop Depth for more than 5 minutes).
  Delayed Violation (a Deco Stop Depth greater than 60 FT/18 M is required).
  Delayed Violation (Maximum Operating Depth of 330 FT/100 M is exceeded).
  A Gas Switch to another tank would expose the diver to PO2 greater than 1.60 ATA.
A single short beep (which cannot be disabled) is emitted for the following -
  Upon completion of a Hot Swap battery change.
  Change from Delayed to Full Violation 5 minutes after the dive.
3 short beeps (which cannot be disabled) are emitted for the following -
  NORM/GAUG Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper than
60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and shallower.
  Air Time Remaining becomes less than No Deco and O2 Time Remaining.
  FREE Dive Elapsed Dive Time Alarm (3 beeps every 30 seconds if set On).
  FREE Dive Depth Alarms 1/2/3 (set sequentially deeper) - each 3 beeps 3 times.
  FREE Dive TLBG Alarm (Caution zone, 4 segments) - 3 beeps 3 times.
  Entry into Deco during a FREE Dive (Permanent Violation) - 3 beeps 3 times.
  Watch Daily Alarm reaches time set (disabled during Dive Modes).
  Watch or Free Dive Mode Countdown Timer reaches 0:00 - each 3 beeps 3 times.