2.1.8.2.1  General Tab 
 
 
Schedule 
Enabled 
Check the “Enabled” box to record a schedule in which the motion alarm can only be 
triggered.  Click the “…” button to open the “Schedule” window or edit an existing 
motion alarm schedule. 
Output Relay 
Output Relay 
When an output relay is selected, the relay is triggered when the motion alarm 
criteria is met. 
Trigger 
There are two trigger types: a momentary trigger of 2 seconds or a latched trigger 
which will stay triggered until motion stops. 
Post Motion Record 
The length of time that the camera continues to record after the motion alarm has stopped being detected. 
 
 
Note:
 Creating or modifying the motion alarm schedule will not affect the schedule created by 
cameras in recording mode “Schedule”.  They are both independent of each other. 
 
3xLogic Vigil System Server Software - User’s Guide    Doc# 08100610 Page 