Infortrend EONSTOR A16E-G2130-4 Manual Do Utilizador

Página de 98
Chapter 5: Subsystem Maintenance and Upgrading  
  Replacing a cooling module: Once you are notified that a cooling module has 
failed, it should be replaced as soon as possible. A failed cooling module should 
only be removed from the subsystem when you have a replacement module 
immediately available. 
  
5.6.2 
Replacing a Cooling Module 
If one of the cooling modules fails, it must be replaced as soon as possible. The 
cooling module is secured to the PSU module with the six (6) screws from the top. To 
replace the cooling module, follow the steps below: 
 WARNING! 
The fan replacement process should be completed within five (5) minutes. If the 
process takes too long, the accumulated heat can damage the subsystem.  
 
 Step 1. 
To remove the cooling module, remove the PSU module first.  
Please follow the PSU removal process listed in the previous 
discussion.   
 Step 2. 
Use a medium-size Phillips screwdriver to remove the six screws 
from the top of the PSU module.  (See Figure  5-12: Removing a 
 
 
Figure 5-12: Removing a Cooling Module 
 Step 3. 
Remove the cooling fan assembly by the following steps: 
Cooling Module Maintenance 
 
5-17