HP AUTOMATIC XT SPAY GUNS 311051D Manual Do Utilizador

Página de 38
Troubleshooting 
22
311051D
Spray Pattern Troubleshooting
Problem
Cause
Solution
Fluid flow is fluttering while spraying. Fluid nozzle is not tight enough.
O-ring (36) is missing or damaged.
Fluid filter is clogged.
Tighten fluid nozzle to 60 in-lb (6.8 
N•m).
Replace o-ring.
Check fluid filter.
Fluid flow fades while spraying high 
viscosity fluids.
Fluid pressure is too low, causing 
fluid flow to reduce when gun is ele-
vated.
Raise fluid pressure at source or use 
a smaller fluid nozzle.
Pattern becomes off-set of heavy on 
ends.
Air cap horn holes plugged or dam-
aged.
Clean air cap horn holes with 
non-metallic item such as a toothpick, 
or replace air cap.
Gun fluid pressure is too high with 
gun triggered.
Using needle/nozzle kit with too small 
orifice.
Use needle/nozzle kit with larger ori-
fice.
Fluid system will not operate at low 
enough fluid pressure [below 10 psi 
(70 kPa, 0.7 bar)].
There is no fluid regulator, or air reg-
ulator on pressure pot is not sensitive 
enough at low pressures.
Add low pressure fluid regulator, or 
add more sensitive low pressure air 
regulator on pressure pot.