Operating Instructions
b
uRneR
L
ighting
:
A) Make sure the pilot is lit.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch to ON.
D) Turn HI/LO knob to the desired flame height.
E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF
Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, or for
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF
Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, or for
servicing, turn the gas shut off valve to OFF. DO NOT
FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for
the first four (4) hours. This will cure the paint, logs, gasket material, and other products used in the
manufacturing process. It is advised that a door or window be opened as the unit will start to smoke,
which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including
the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas
fireplace glass cleaner, available at your local Enviro dealer. See M
aintenance
a
nd
S
ervice
- c
leaning
t
he
g
laSS
and M
aintenance
a
nd
S
ervice
- g
laSS
d
oor
r
eMoval
.
b
LoweR
s
PeeD
:
The blower will come on only when the fireplace is up to temperature (approximately
20 minutes). The speed of the fan can be changed by turning the fan control knob.
To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off
(Figure 7).
It is advisable not to operate the blower below
It is advisable not to operate the blower below
1
/
3
speed as it puts a strain on the
windings of the blower and running the blower at lower speeds could also cause
premature fan failure.
R
emote
c
ontRoLs
:
This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of
these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the
control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall
thermostat for operation guidelines.
thermostat for operation guidelines.
n
oRmaL
s
ounDs
D
uRing
o
PeRation
:
Table 1: Normal Sounds
Component
Sound & Reason
DV42DX & Fascia
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The blower is
pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
Figure 6. Control Panel
Figure 7. Fan Control
HI
OFF
LO
8