Periodically check to ensure that your system is clean. 
 
Periodically check the pilot and burner.  Check to see that 
all the burner ports are clean and clear.  Check the pilot 
head for blockage.  Check to ensure the pilot flame is blue 
with no yellow tips. 
 
OPENING THE DOOR 
 
Turn unit off and wait until the appliance has cooled down. 
Open the lower louver panel.  Undo the three bolts at the 
bottom corners and center of the door. Swing door out, 
then lift up and out to remove. 
Ensure the door is properly fastened after cleaning before 
attempting to re-light the appliance.
 
 
CLEANING THE GLASS
 
 
DO NOT CLEAN GLASS WHEN HOT 
 
It will be necessary to clean the ceramic glass periodically.  
During a cold start up, condensation will sometimes form 
on the glass, this is a normal condition with all gas 
fireplaces and stoves.  However, this condensation can 
allow dust and lint to cling to the glass surface. Initial paint 
curing of the appliance can leave behind a slight film on 
the glass.  This is a temporary problem. It is therefore 
recommended that the glass be cleaned initially after 
about the first two weeks of use. 
 
To clean the door use a mild glass cleaner and a soft 
cloth.  Abrasive cleaners will damage the glass and gold 
surfaces. 
 
TO REPLACE DOOR GLASS  
 
The glass in this appliance is ceramic.  If the glass is 
damaged or broken a factory replacement must be fitted. 
 
TO REPLACE: 
• 
Open door, remove the glass carefully. 
• 
Install the new piece of glass with the large bulb in the 
gasket tape against the unit.  Place the joint in the 
tape in a bottom corner.  Close door
 
 
Glass must be purchased from an Envirogas dealer.   
No substitute materials are allowed. 
 
CLEANING THE INSIDE OF THE FIREBOX 
 
Remove the log carefully from the firebox.  Gently remove 
the embers and place on a piece of paper towel.  Until 
ready to replace. 
 
Vacuum the bottom of the firebox thoroughly.  Carefully 
clean off any dust on the logs and brick panels and 
remove any lint from the main burner and pilot burner. 
 
After carefully replacing the log and embers in their correct 
positions, and the door has been resealed, re-light the 
pilot, following the instructions on the attached label. 
 
CLEARANCES MUST BE SUFFICIENT TO ALLOW 
ACCESS FOR MAINTENANCE AND SERVICE 
 
Depending upon the amount of use, cleaning should be 
required no more than two or three times per season. 
 
REMOVING BURNER CONTROLS: 
 
1.  Shut of gas supply to appliance. 
2.  Disconnect gas line from the valve. 
3.  Open the door and remove the log.  Remove the 
burner tray assembly by removing the two screws on 
either side of the tray.  Pull tray up at the back, lift tray 
out and towards the front. 
4.  Remove the brick panel as per instructions.  Undo the 
(6) six screws that hold the burner control tray onto 
the base of the unit. Lift the control tray, up on the left 
side and pull out. 
5.  Installation is the reverse  
 
CAUTION:  
 
Bleed lines before lighting and light pilot 
with door open 
 
ADJUSTING VENTURI AIR SETTINGS 
 
There is a separate venturi air shutter for each burner The 
venturis have been set for installation at sea level. 
 
To adjust for high altitude: open the lower louvers, 
Locate the venturis between the burner and control 
trays.  Loosen the 2 set screws with a long 
screwdriver and rotate the air shutters to the correct 
setting. 
 
 
 
 
 