1-800-DR-OWNER         13
 
 
• 
IT IS IMPORTANT TO ADJUST THE AIR BLEED SCREW EACH TIME YOU USE THE MACHINE. YOU 
WILL NEED A STANDARD PHILLIPS SCREWDRIVER
 
TO MAKE THIS ADJUSTMENT (
FIGURE 3). 
• 
USE CARE, DO NOT OVER TIGHTEN AND STRIP THE AIR BLEED SCREW THREADS. 
CHAPTER 4 
OPERATING YOUR DR 6 -TON ELECTRIC WOOD SPLITTER 
 
This chapter covers the procedures for operating your new DR 6 -TON ELECTRIC WOOD SPLITTER and 
discusses basic operation features.  You may find it helpful to review the Controls and Features on page 10. 
Before Starting the Electric Motor 
Tools Needed:  
• 
Adjustable Wrench 
• 
Small Phillips Screwdriver
 
1.  Inspect the area in which you will be working. 
• 
Place the wood splitter only on a firm, level, supported surface 2 to 3 feet above the ground. 
• 
NEVER operate the wood splitter on the ground as there is risk of injury from flying chips and 
would not be comfortable for the operator while in use.  If necessary, block the wood splitter 
wheels to prevent them from rolling. 
• 
The site must be free of slippery surfaces and potentially hazardous obstacles.  Also make sure 
there won't be people or animals within a six-foot radius around the wood splitter. 
2.  Plan your work before you start. 
• 
Have the logs to be split positioned where they can be easily reached.  Remember, the maximum 
log length is 20" and the maximum diameter is 16" for this wood splitter. 
• 
Split only dry, seasoned logs as they will split more easily than green logs.  Green logs may stick 
on the wedge and jam the wood splitter. 
• 
Have a site located where the split wood can be stacked or loaded onto a truck or nearby carrier.
 
 
 
 
 
  
 
 
3.  Prior to using the wood splitter, open the Air 
Bleed Screw by turning it counter-clockwise four 
(4) times. Leave the Air Bleed Screw open in this 
position while using the machine.
  When you are 
finished using the machine, tighten the Air Bleed 
Screw by turning it clockwise.  Do not over tighten 
and strip the Air Bleed Screw.
 Air Bleed Screw 
Figure 3