Specific Instructions
Station Port / Centrex Connections
Disconnect Methods
In station port operation, the UPAM provides CPC (calling-party-controlled) [loop
current interruption] disconnect, default timer disconnect, or optional voice-
operated (VOX) disconnect. The calling-party-controlled disconnect recognizes a
line-issued disconnect signal and immediately disengages the UPAM from the line
(this feature cannot be adjusted or inhibited). The default timer causes the UPAM to
release after a user-determined period of time ensuring that the UPAM will always
disengage the line if the other disconnect functions are disabled or inoperative. (The
default time is approximately 6 to 35 seconds, but can be increased or inhibited; see
Inhibit Default Timer and Changing Default Timer Range on page 16.) The voice-
operated (VOX) disconnect feature has the ability to pre-empt the default timer and
disconnect the line after a predetermined interval of silence (approx. 2 to 6 seconds,
set with VOX DELAY) has elapsed. The VOX feature is turned on or off with
MODE switch S5.
IMPORTANT
No power supply is used for Station Port/Centrex operation. Mode
switches S1, S2 and All AUX switches are not operable.
Procedure
1.
2.
Set MODE switches S3 and S4 for Pre-announce or Confirmation tone (as desired).
NOTE:
One of these modes must be selected for UPAM to operate correctly.
3.
Set MODE switch S5 in the OFF position.
4.