Avaya Bogen Universal Paging Access Module Instrução De Instalação
[13]
Specific Instructions
Station Port / Centrex Connections
Disconnect Methods
In station port operation, the UPAM provides CPC (calling-party-controlled) [loop
current interruption] disconnect, default timer disconnect, or optional voice-
operated (VOX) disconnect. The calling-party-controlled disconnect recognizes a
line-issued disconnect signal and immediately disengages the UPAM from the line
(this feature cannot be adjusted or inhibited). The default timer causes the UPAM to
release after a user-determined period of time ensuring that the UPAM will always
disengage the line if the other disconnect functions are disabled or inoperative. (The
default time is approximately 6 to 35 seconds, but can be increased or inhibited; see
Inhibit Default Timer and Changing Default Timer Range on page 16.) The voice-
operated (VOX) disconnect feature has the ability to pre-empt the default timer and
disconnect the line after a predetermined interval of silence (approx. 2 to 6 seconds,
set with VOX DELAY) has elapsed. The VOX feature is turned on or off with
MODE switch S5.
current interruption] disconnect, default timer disconnect, or optional voice-
operated (VOX) disconnect. The calling-party-controlled disconnect recognizes a
line-issued disconnect signal and immediately disengages the UPAM from the line
(this feature cannot be adjusted or inhibited). The default timer causes the UPAM to
release after a user-determined period of time ensuring that the UPAM will always
disengage the line if the other disconnect functions are disabled or inoperative. (The
default time is approximately 6 to 35 seconds, but can be increased or inhibited; see
Inhibit Default Timer and Changing Default Timer Range on page 16.) The voice-
operated (VOX) disconnect feature has the ability to pre-empt the default timer and
disconnect the line after a predetermined interval of silence (approx. 2 to 6 seconds,
set with VOX DELAY) has elapsed. The VOX feature is turned on or off with
MODE switch S5.
IMPORTANT
No power supply is used for Station Port/Centrex operation. Mode
switches S1, S2 and All AUX switches are not operable.
switches S1, S2 and All AUX switches are not operable.
Procedure
1.
Mount and ground the UPAM as described in General Instructions (pages 7 - 8).
2.
Set MODE switches S3 and S4 for Pre-announce or Confirmation tone (as desired).
NOTE:
One of these modes must be selected for UPAM to operate correctly.
3.
Set MODE switch S5 in the OFF position.
4.