Apex 1 to 5.5 kW Generator
DeviceNet is connected through pins 1, 10, 13, 14, and 15 of the User port (See table 
4-1).
When the generator powers up, it defaults to user control mode. However, engaging 
DeviceNet automatically places the generator in host control mode. Note that when 
the generator is in host control mode, the regulation mode is forward power.
Before operating your Apex generator through the DeviceNet port, ensure that your 
network is connected to the DeviceNet port and the User port. Also, ensure that you 
have selected an appropriate MAC ID and baud rate. Finally, ensure that you have 
read the following information about command and response messages and the 
DeviceNet LEDs.
DeviceNet Poll Command Message
Note that this device uses DeviceNet’s Group 2 I/O Poll Command message (and the 
associated Group 1 I/O Poll Response message) to transfer low-level I/O data between 
the device (slave) and the master. Table 4-16 represents the structure of the poll 
command message.
Power Output Setpoint 0 to 10 V; 10 V = full output power of the power supply 
PO = Power On
1 = turns power supply’s output ON
0 = turns power supply OFF
Note: The 16-bit AI should be shifted right four bits and the remaining first four bits 
should be filled with 0s. This changes the 16-bit AI to a 12-bit AI with a value 
of 10 V = OFFF
hex
.
Note: Power Output Setpoint values exceeding OFFF
hex 
are limited to OFFF
hex
.
DeviceNet Response Message
Table 4-17 represents the structure of the response message.
Table 4-16. Poll Command Message
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Power Output Setpoint AI (LSB)
1
0
0
0
0
Power  Output  Setpoint  AI 
(MSB)
2
0
0
0
0
0
0
0
0
3
0
0
0
0
0
0
0
0
4
PO