Apex Digital 5708009-C Manual Do Utilizador

Página de 160
5708009-C
4-79
Apex 1 to 5.5 kW Generator
APEX STATUS INDICATORS (LEDS)
Some Apex generators provide the following status indicators on the front or rear 
panel. For panel illustrations, see “Apex Panel Illustrations” on page 4-80.
This section of the manual provides information for the:
Passive digital display option
PIN position 5
, (A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17) option 2
(When identifying the PIN position, remember that the A at the beginning of 
the PIN is not counted as a position. The PIN option is the number or letter 
you should look for in the specified position.)
For more information about the PIN and for a complete list of how PIN 
positions correspond to Apex product options, see
 Table 1-1. on page 1-4.
Table 4-18. LED Status Indicators
Indicator
Description
AC ON
This green LED indicates that ac power is available within 
the generator and all three phases are present.
RF ON
This green LED indicates that RF power is on (enabled). 
Depending on the selected setpoint value, RF power may 
or may not be present at the output connector.
A flashing LED indicates an error. See “Troubleshooting 
guide” on page 6-1.
INTERLOCK 
When lit this green LED indicates that the required 
interlock criteria has been satisfied. The interlock must be 
satisfied before the output can be enabled. The LED 
remains on as long as the interlock loop is satisfied. If you 
suspect an error and this LED is off, see “Troubleshooting 
guide” on page 6-1.
POWER LIMIT
When lit, this yellow LED indicates that the generator is 
unable to supply the requested power level due to a 
limiting condition in the generator. Power limits do not 
disable the RF output of the generator. If you suspect an 
error and this LED is lit, see “Troubleshooting guide” on 
page 6-1.