APEX PANEL ILLUSTRATIONS
The appearance of the front and real panels of the Apex generator is highly variable 
due to the number of customer-selectable options available in the product line. These 
options mean that the presence or absence or certain connectors, the types of 
connectors, and the locations of certain options (on the front or the rear panel) are 
variable. The following illustrations show a basic Apex option, with labels for the 
options that you may or may not have on your Apex unit. To find information about 
any of these options, see “Using this Manual to Find Information for Your Generator” 
on page 1-1.
OVERTEMP
A flashing yellow LED warns that the internal cold plate 
temperature is approaching the shutdown limit. 
A continuously lit LED indicates that the internal cold 
plate temperature has exceeded the allowable limit. When 
this condition occurs, the RF turns off and can be turned 
back on only after the temperature drops below the 
warning temperature limit and a RF Off command is given 
to clear the fault. See “Troubleshooting guide” on page 6-1 
for more information.
ALARM
This yellow LED indicates that the generator has turned off 
RF output due to some limit or alarm condition in the 
generator. Some of the conditions that can cause an alarm 
are:
Over-temperature
Exceeded internal protection limits
AC PWR outside the limits
In the event of an alarm condition, after correcting the fault 
condition, an RF OFF signal has to be given to reset the 
generator since the generator has turned off RF output. See 
“Troubleshooting guide” on page 6-1 for more 
information.