4-7
Apex 1 to 5.5 kW Generator
7
20
DC BIAS INPUT
Analog 
input
This pin is used in conjunction 
with signal pin 6 to allow the 
generator to regulate its power 
based on an external feedback 
signal. This User defined 0 to 10 
V signal provides an input which 
you can use for closing the 
power control loop around 
external components in the RF 
path. Usually used for bias 
regulation with this input signal 
being a scaled representation of 
the dc bias measured at match 
network. 
Note: When using this 
regulation feature, the 
setpoint must be given at 
pin 5 (SETPOINT). 
Setpoints cannot be 
established through the 
serial interface at this 
time.
8
21
FWD/LOAD PWR 
REGULATION
Digital 
input
Applying a positive dc voltage 
between 4 and 30 V to this pin 
causes the generator to regulate 
on load power. No connection to 
this pin causes the generator to 
default to forward power 
regulation.
9
OVERTEMP 
RETURN
Digital 
Output
See Signal pin 22
10
23
INTERLOCK LOOP
This pin when connected 
externally to pin 23 closes the 
interlock and allows the RF 
output to be enabled.
Table 4-1. User Port 25-Pin APEX Standard Pin Descriptions (Continued)
Signal 
Pin
Return 
Pin
 Name
Signal 
Type
Description