Apex 1 to 5.5 kW Generator
WIRING DIAGRAMS FOR THE STANDARD 25-PIN USER PORT
The diagrams in this section provide wiring information to properly connect to the 
Apex standard 25-pin User port.
22
9
OVERTEMP
Digital 
output
When an internal 
overtemperature shutdown 
condition is detected, a low 
(opto-coupler output) impedance 
is created between this pin and 
pin 9 (6 mA max).
Note: This pin only detects a 
overtemp shutdown 
condition. The warning 
indication described in the 
Overtemp LED section is 
not reported on this pin.
23
10
INTERLOCK LOOP 
RETURN
See Pin 10.
24
11
DC BUS OK
Digital 
output
When the interlocks are satisfied 
and the AC input voltage is 
within its specification, a low 
(opto-coupler output) impedance 
is created between this pin and 
pin 11 (6mA max).
25
 CEX LOCK 
RETURN
Digital 
Output
See pin 12