Apex Digital 5708009-C Manual Do Utilizador

Página de 160
5708009-C
4-53
Apex 1 to 5.5 kW Generator
171
read ext 
feedback 
limit
Requests external feedback limit (set by 
CMD 6)
Note: The response in data bytes 1 and 2 
represent the user external feedback 
limit (LSB first). It returns the user 
external feedback limit.
2 data bytes
16-bit value
173 report 
power 
dissipation
Reports dissipated power
Note: The response in data bytes 1 and 2 
represent dissipated power (LSB first). 
It returns dissipated power.
2 data bytes
16-bit value
184
read out-of-
setpoint 
interval
Requests how long the generator is 
programmed to produce output that is not 
equal to the programmed setpoint level 
before shutting output off (set with CMD 15).
Note: Data bytes 1 and 2 represent the 
unsigned integer value for out of 
setpoint time interval (LSB first). It 
reports how many seconds the 
generator will produce output that is 
not equal to the setpoint before turning 
the output off.
2 data bytes
16-bit value
185
read 
allowable 
deviation
Requests what percentage the generator can 
be out of setpoint before it starts the out-of-
setpoint timer (set with CMD 16).
Reports the allowable setpoint deviation
Note: The response reports the percentage (1 
to 99) and the supply can be out of 
setpoint before turning on the out-of-
setpoint timer.
1 data byte
8-bit value
Table 4-6. Host Port Commands for RS-232 with AE Bus  (Continued)
Command
Description
Number of 
Host Data 
Bytes
Number of 
Response 
Data Bytes