NOTES: 1 ) MAGIC FORCE AUX. SWITCH #4 SHOULD OPEN AT APPROX.  65-70 DEGREES.  FOR MAGIC SWING REFER TO INHIBIT SWITCH BEA PT# 10 SSINHL OR 10SSINHR.
2 ) THE BODYGUARD RELAY OUTPUT FUNCTION MUST BE CHANGED TO #2.
3 ) SHOWN LH,RH MAGIC SWING AND RH MAGIC FORCE FOR LH MAGIC FORCE REVERSE RED AND BLACK WIRES.
4 ) DOOR CONTROL SW2 SWITCH BANK SET DIPSWITCH # 1 & 3 TO THE OFF (TIMER) POSITION.
5 ) JUMPER 6 & 8.
6 ) INSTALL BLUE WIRE INTO PIN 6. INSTALL WHITE WIRE INTO PIN 1
LEFT APPRCH SIDE SSCAN
RIGHT APPRCH SIDE SSCAN
EAGLE
N.C.        5
N.O.        4
green
COM       3
white
POWER  2
black
POWER  1
red
TITLE: STANLEY MP CONTROL WITH LO-21P
PARALLAX II SYSTEM Q-DISCONNECT
ON SAFETY SIDE
80.0188.04
RIGHT SAFETY SIDE SSCAN
LEFT SAFETY SIDE SSCAN
BODYGUARD
RED
GREEN
OFF
ON
LO21 P
GREEN
BLUE
HOLD OPEN
AUTO
OFF
24 V 
TRANSFORMER
SUPERSCAN QUICK
DISCONNECT CABLE
SUPERSCAN QUICK
DISCONNECT CABLE
Common
N/O
N/C
MAGIC FORCE
AUXILLARY SWITCH 4
(SEE NOTE # 1)
1  COMMON
2  OPERATE
3  SENSOR OP 
4  12 VAC
5  12 VAC
6  AUX INPUT
7  SAFETY/STALL
8  COMMON
INSTALL JUMPER
IF NO BREAKOUT
SWITCH.
BLACK -
BLACK
WHITE
YELLOW
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME
AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE
ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER
SACRIFICE THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM