maximum BTU/H rating on the pressure relief valve is equal to or greater than the maximum input BTU/H rating of the combination 
water heater. 
 
 
To avoid water damage or scalding due to relief valve operation: 
 
Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line in a 
manner that will prevent possibility of severe burns or property damage should the relief valve discharge. 
 
Discharge line must be as short as possible and the same size as the valve discharge connection throughout its entire length. 
 
Discharge line must pitch downward from the valve and terminate at least 6” above the floor drain, making discharge clearly 
visible. 
 
Discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375
o
F or greater. 
 
Do not pipe discharge to any location where freezing could occur. 
 
No shutoff valve may be installed between the relief valve and water heater or in the discharge line. Do not plug or place any 
obstruction in the discharge line. 
 
Test the operation of the relief valve after filling and pressurizing the system by lifting the lever. Make sure the valve 
discharges freely. If the valve fails to operate correctly, replace it with a new relief valve. 
 
Test relief valve at least once annually to ensure the waterway is clear. If valve does not operate, turn the water heater 
“off” 
and call a plumber immediately. 
 
Take care whenever operating relief valve to avoid scalding injury or property damage. 
 
For water heaters installed with only a pressure relief valve, the separate storage vessel must have a temperature and 
pressure relief valve installed. This relief valve shall comply with Relief Valves for Hot Water Supply Systems, ANSI Z21.22 
CSA4.4.
 
 
FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION, 
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH. 
PART 9 – CONNECT ELECTRICAL POWER / INITIAL STARTUP 
 
Install wiring and electrically ground water heater in accordance with the authority having jurisdiction or, in the absence of such an 
authority, follow the National Electrical Code, NFPA 70, and/or CSA C22.1 Electrical Code-Part 1 in Canada. Failure to follow all 
applicable local, state, and national regulations, mandates, and building supply codes for guidelines to install the electrical power supply 
could result in property damage, serious personal injury, or death. 
 
 
ELECTRICAL SHOCK HAZARD 
– To ensure safety, turn off electrical power supply at service entrance panel before making any 
electrical connections to avoid possible electric shock hazard. Failure to do so could result in property damage, serious personal injury, 
or death. 
A. WIRING INFORMATION 
1. This water heater must be properly grounded. Ensure the electrical receptacle that the water heater will be plugged into is properly 
grounded. 
 
2. Do not attach the ground wire to either the gas or water piping. 
 
Figure 19 
– Proper Grounding – Internal Manual Power Switch