HP Cell Phone Accessories E6380-90019 Manual Do Utilizador

Página de 228
100
Chapter 4 
CDMA Measurements - Screens and Control Fields
Even Sec In
Gain
Even Sec In
This field controls the internal connection of the EVEN SECOND 
SYNC IN connector to the CDMA analyzer. 
• When 
Enable
 is selected, signals applied to the EVEN SECOND 
SYNC IN connector synchronize the timing circuits.
• When 
Not
 is selected, input signals applied to the EVEN SECOND 
SYNC IN are ignored. This mode may be useful when signals other 
than an even-second clock are used for synchronization. For 
example, when using a one-second clock, you would select 
Not
 after 
synchronization to prevent the internal even-second clock from being 
retriggered half-way through its cycle.
Screens on which this field is present
CDMA ANALYZER
CDMA GENERATOR
Freq Err
This measurement display field displays the frequency offset (frequency 
error). See 
 for more information about 
this measurement.
Screens on which this field is present
COD DOM (Code Domain Analyzer)
Gain
This field sets the IF gain of the CDMA analyzer for rho, EVM, and 
channel power measurements. (Range: 0 dB to 36 dB in 6 dB steps.)
Gain is adjusted two ways: 
Auto
 measures the signal level and automatically adjusts the gain. 
Hold
 disables automatic operation to allow you to manually enter 
the desired gain by selecting the current gain setting and entering a 
new value using the keypad or cursor control knob.
This field is replaced by the 
Pwr Gain
 field when measuring average 
power. See the 
 for more information.
Screens on which this field is present
CDMA Analyzer
COD DOM (Code Domain Analyzer): gain controls menu
Main Menu