CDMA Measurements - Screens and Control Fields
Input Port
Meas Intvl
Input Port 
This field selects which Test Set port to use as the RF input. This field 
is not displayed when measuring average power, since you must use the 
RF IN/OUT port to measure average power. 
CAUTION
Instrument Damage 
To prevent instrument damage, do not exceed the 
maximum power level labeled at the connectors on your 
Test Set. The ANT IN connector is for measuring low level 
RF signals. High level (>60 mW) transmitter signals must 
be measured using the RF IN/OUT port. 
Screens on which this field is present
CDMA ANALYZER
CODE DOM (Code Domain Analyzer): main controls menu
Lvl
This measurement displays the relative level of the selected Walsh 
channel when compared to the total power in a 1.23 MHz bandwidth 
centered around the 
Tune Freq
 setting. The measurement is displayed 
when the code domain analyzer’s main controls 
Measurement
 field is 
set to 
Power
 or 
Fast Pwr
.
Screens on which this field is present
COD DOM (Code Domain Analyzer): marker controls menu
Meas Intvl
This field determines the length of the data block. The data block is a 
time record over which correlated measurements are computed. As the 
interval is increased, measurement time is increased. Increasing the 
interval gives more accurate measurement results, particularly with 
frequency error and phase error measurements.
This field is displayed on the CDMA ANALYZER screen when a rho or 
EVM measurement is selected. It is also displayed on the CODE DOM 