Analog Measurements - Screens and Control Fields
Ext Load R
Filter 1
Ext Load R
External load resistance is used to calculate and display AF power. 
Power is calculated using the voltage measured at the AUDIO IN 
connections and the resistance value you enter into this field.
This field is displayed only when the 
Audio In
 field on the AF 
ANALYZER screen is set to 
GND
 or 
Float
.
Operating Considerations
To display audio power, set the 
AC Level
 measurement’s unit of 
measure to 
W
 (watts).
Screens on which this field is displayed
AF ANALYZER
Filter 1 
This field selects an audio frequency filter which can be used to 
condition the audio signal before it is analyzed by the audio frequency 
analyzer. 
The following filter choices are available:
• <20 Hz HPF
• 50 Hz HPF
• 300Hz HPF
• C  MESSAGE
Operating Considerations
The audio from the Test Set’s speaker is not affected by Filter 1 or 
Filter 2 settings.
Screens on which this field is displayed
AF ANALYZER