89
CDMA Measurements - Screens and Control Fields
Code Domain Measurements
Code Domain Measurements
Code Domain Measurements
The following measurements are displayed on the CODE DOM (code 
domain analyzer) screen: power, fast power, timing and phase. 
Measurements are selected from the 
Measurement
 field on the 
Main
 
controls menu.
Time offset (Tm Ofs) and frequency offset (FreqOfs) are always 
displayed when any code domain measurement is made. Carrier 
feedthrough (CarFT) is also displayed except when fast power is 
measured.
Code Domain Power
#ODE $OMAIN
&REQUENCY $OMAIN
0
1
2
3
4
5
6
7
8
9
 
32
 
 
 
63
User
1
User
3
User
2
Walsh Code
Pilot Paging
Synch
User #2
User #1
Synch
Paging
Pilot
1.2288 MHz
freq
Other users & noise
Code Domain
Frequency Domain