HP Cell Phone Accessories E6380-90019 Manual Do Utilizador

Página de 228
Chapter 4
91
CDMA Measurements - Screens and Control Fields
Code Domain Measurements
Code Domain Measurements
Fast Power
Fast power is a faster method of measuring code domain power. A value 
for Time Offset must be transferred from a non-fast power 
measurement before fast measurements begin, or when changes to any 
of the following fields occur: 
Data Rate
PN Offset
CDMA TB
Synth 
Ref
.
See the 
 for more information.
The number of measurement averages can be entered in the Num Avgs 
field on the FP Setup menu. This number is used to calculate and 
display successive code domain power measurements.
Screens on which this measurement is displayed. 
• CODE DOM (Code Domain Analyzer)
Code Domain Timing (Timing)
Code domain timing is the difference in time between pilot (Walsh 0) 
and other Walsh codes with the same forward CDMA channel. In the 
CODE DOM screen, this measurement is indicated as positive or 
negative bar with the size of the bar indicating how far ahead or behind 
the other Walsh channels are relative to the pilot. Signals above the 
reference are leading in time; signals below the reference are lagging. 
(See 
.) 
Screens on which this measurement is displayed. 
• CODE DOM (Code Domain Analyzer)
Main Menu