WARNING
UNDER NO CIRCUMSTANCES SHOULD THE INPUT EXCEED THE RATE 
SHOWN ON THE HEATER RATING PLATE. OVER FIRING COULD RESULT 
IN DAMAGE OR SOOTING OF THE HEATER.
CATHODIC PROTECTION
 
CAUTION
HYDROGEN  GAS  CAN  BE  PRODUCED  IN A  HOT  WATER  SYSTEM 
SERVED BY THIS HEATER THAT HAS NOT BEEN USED FOR A LONG 
PERIOD OF TIME (GENERALLY TWO WEEKS OR MORE). HYDROGEN 
GAS IS EXTREMELY FLAMMABLE. 
To reduce the risk of injury under these 
conditions, it is recommended that a hot water faucet be opened for several 
minutes before using any electrical appliance connected to the hot water 
system. If hydrogen is present, there will probably be an unusual sound such 
as air escaping through the pipe as the water begins to flow. There should 
be no smoking or open flame near the faucet at the time it is open.
PRECAUTIONS
IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERATE 
HEATER  UNTIL ALL  CORRECTIVE  STEPS  HAVE  BEEN  MADE  BY A 
QUALIFIED SERVICEMAN.
1.  FLOODING TO OR ABOVE THE LEVEL OF THE BURNER OR CONTROLS
2.  EXTERNAL FIRING
3.  DAMAGE
4.  FIRING WITHOUT WATER
5.  SOOTING
NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS 
FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF 
VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF THE HEATER.
SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, 
TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.
GENERAL INFORMATION
POWER BURNER
The initial start-up procedure of the unit is provided on page 18.
The sequence of operation of the unit is provided on page 15.
It is important to note that the controller has a reset button on the control 
box, Figure 1. The reset button is a safety device and would not normally 
be used.
HIGH LIMIT
The high limit (not adjustable) is factory set to cutout at 202°F (94°C). The 
controller must be manually reset by depressing the reset button on front of 
the control when water temperature drops to below 160°F (71°C).
TABLE 4
HIGH ALTITUDE INSTALLATIONS
 WARNING
THE (A)JWSH100199 AND (A)JWSH100250 HEATERS ARE CERTIFIED FOR USE 
WITHOUT MODIFICATION FOR ALTITUDES UP TO 10,100 ft. (3078 m). THE (A)
JWSH100150 HEATERS ARE CERTIFIED FOR USE WITHOUT MODIFICATION 
FOR ALTITUDES UP TO 7,700 ft. (2347 m). INSTALLATIONS ABOVE THESE 
ALTITUDES MAY REQUIRE REPLACEMENT OF THE BURNER ORIFICE. CALL 
THE TECHNICAL CENTER @ (888) 479-8324 FOR REQUIREMENTS.
Some gas utility companies derate their gas for altitude, making it  unnecessary 
to install high altitude orifices.  Call the local gas or utility company to verify 
BTU content.
Due to the input rating reduction at high altitudes, the output rating of the 
appliance is also reduced and should be compensated for in the sizing of 
the equipment for applications.
MAINTENANCE
GENERAL
KEEP APPLIANCE AREA  CLEAR AND  FREE  FROM  COMBUSTIBLE 
MATERIALS,  GASOLINE AND  OTHER  FLAMMABLE  VAPORS AND 
LIQUIDS. (SEE WARNING ON PAGE 5, LOCATING THE HEATER).
Water heater maintenance includes periodic tank flushing and cleaning, and 
removal of lime scale. The unit should be inspected and adjusted to maintain 
proper combustion. Refer to the following table. A periodic inspection of the 
venting system should be made. Where used, the water circulating pump 
should be oiled.
MAINTENANCE SCHEDULE
Following  are  the  instructions  for  performing  some  of  the  recommended 
maintenance.  Unit  inspection  and  adjustment  should  be  performed  by  a 
competent technician.
TABLE 5
  COMPONENT  OPERATION  INTERVAL 
REQUIRED
 
Tank
 
Sediment 
Monthly 
Flushing
 
 
Removal 
 
 
 
Tank 
Lime Scale 
Semi  
UN-LIME
®
 
 
Removal 
Annually 
Delimer
  Relief Valve 
Inspect 
Semi
 
 
 
Annually
 
 
 
Clean Inlet
 
Blower 
Screen and 
As Required 
Soft Brush
 
 
Blower Wheel
  Vent System 
Inspect 
Every 3 
Joints should
 
 
 
Months 
be sealed