Yamaha SP2060 V1 Manual Do Proprietário

Página de 57
Network Settings
SP2060 Owner’s Manual
Fore
w
o
rd
Netw
ork Settings
Ref
erences
P
anel Operation
Intr
oduction 
to the SP2060
The Contr
ols 
and Connector
s
38
6.
To confirm the setting, press the [YES] key.
The setting is applied and the unit returns to the IP Ad-
dress page.
Setting the Master ID
The SP2060 units that are assigned as slaves in a device 
group follow the master SP2060 in the same group via com-
munication. Follow the steps below to set the master ID on 
the slave SP2060 units. Use the 4th octet of the IP address of 
the master unit as the Master ID parameter value. 
1.
Press the [UTILITY] key to select the Utility 
display.
The most recently used Utility display will appear.
2.
Press the [UTILITY], [NEXT] or [BACK] key 
repeatedly until the Master ID page appears.
3.
Press the [
INC]/[DEC] keys to set the 
value to the same number as the 4th octet of 
the master SP2060 IP address.
4.
Press the [NEXT] key to move the cursor to 
the 
 icon, then press the [YES] key.
A confirmation message will appear.
5.
To confirm the setting, press the [YES] key.
The setting is applied and the unit returns to the Master 
ID page.
To cancel the operation and return to the original set-
ting, press the [NO] key, instead of the [YES] key.
Setting Link Mode
Follow the steps below to select 100Base-TX or 10Base-T for 
the [NETWORK] connector speed. 
100Base-TX
The [NETWORK] connector basically operates as 100Base-
TX, but automatically switches to 10Base-T if the network 
environment is not compatible with 100Base-TX. 
10Base-T
The [NETWORK] connector is compatible with 10Base-T 
operation. 
1.
Press the [UTILITY] key to select the Utility 
display.
The most recently used Utility display will appear.
2.
Press the [UTILITY], [NEXT] or [BACK] key 
repeatedly until the Link Mode page appears.
3.
Press the [
INC] key to select 100Base-TX, 
and the [
DEC] key to select 10Base-T.
When you change the setting, the parameter setting 
flashes.
4.
Press the [NEXT] key to move the cursor to 
the 
 icon, then press the [YES] key.
A confirmation message will appear.
5.
To confirm the setting, press the [YES] key.
The unit reflects the edit and returns to the Link Mode 
page.
NOTE
This parameter can be set from 2 through 253.
MASTER ID
     253
MASTER ID
ARE YOU SURE?    
NOTE
Depending on the specifications of the connected network 
devices (such as a switching hub, router, etc.), changing Link 
Mode may cause the SP2060 to be unable to reconnect to the 
network. In this case, turn the power to the SP2060 off and then 
on. The SP2060 will reconnect to the network.
LINK MODE
   100BASE-TX
LINK MODE
     10BASE-T    
LINK MODE
ARE YOU SURE?