Toshiba Robotics SR-554HSP Instrução De Instalação

Página de 21
 
                                                                   
STE 58764 
-    -
 
2-20 
2.3.4    Precautions for Direct Installation 
 
When two or more controllers are used, it is necessary to provide a clearance of 50 mm or 
more in the horizontal direction and a clearance of 100 mm or more in the vertical 
direction between the controllers. 
 
 
Caution 
  Provide a ventilation space at the side of the controller so that the air vent holes are not 
blocked.    The space equal to the length of the support should be kept below the lower 
surface. 
 
Failure to do so could cause the cooling performance to drop or to faults. 
  Do not stack the controllers or place objects in front of it. 
Fig. 2.23    Controller ventilation space 
 
2.4  PRECAUTIONS FOR HANDLING THE TEACH PENDANT 
 
Be careful of the following when handling the teach pendant. 
 
 
Caution 
 
  Do not drop the teach pendant or hit it against anything. 
  Do not pull on the cable protruding from the teach pendant. 
  Do not press the switches on the teach pendant with anything sharp (like the tip of a knife, 
pencil, ball-point pen, etc.). 
  Do not place or use the teach pendant near open flames. 
  Do not leave the teach pendant in direct sunlight for a long period of time. 
ON
OFF
START
STOP
CYCLE STOP
MANU
INT
EXT
FAULT
POWER
SERVO POWER
EMERGENCY
BATTERY
ALARM
J1
J2
PC
FDD
TP
C.P.
CC24V
10AT
POWER
50mm or more
50mm or more
11mm