To set up the vertical position:
Cursor
Write the vertical position of the cursor to the SVP[9:0] field 
(x’007F14’).
Valid range: x’3F0’ 
 (no. of H scan lines) 
 SHP 
 x’03’
When you write new values to 
the GIVP and CIVP fields, the 
settings take effect on the next 
VSYNC pulse. This means that 
changes are reflected in the next 
display screen rather than the 
current one.
Graphics
Write the vertical position of the first line in the display to the 
GIVP[9:0] field (x’007F18’).
Write the position of the second and all following lines in the GVP[9:0] 
field of the graphics display RAM data for the preceding line.
Valid range: x’3F0’ 
 (no. of H scan lines) 
 GIVP/GVP 
 x’03’
Text
Write the vertical position of the first line in the display to the 
CIVP[9:0] field (x’007F1C’).
Write the position of the second and all following lines in the CVP[9:0] 
field of the text display RAM data for the preceding line.
Valid ranges: x’3F0’ 
 (no. of H scan lines) 
 CIVP/CVP 
 x’03’
VP range calculation example
The base graphics line height is 16 dots, or H scan lines. If the graphics line you 
are positioning displays at 2x the base height, the number of H scan lines is:
16 
×
 2 
=
 32 
=
 x’20’ H scan lines
The valid range of settings for GVP is:
x’3F0’ 
 x’20’ 
=
 x’3D0’ 
 GVP 
 x’03’
About the vertical start position on the screen
The vertical position, or VP settings (SVP, GVP, and CVP) determine where the 
upper edge of cursor, graphics, and text lines start on the screen. You can set this 
value for all of the layers in H scan line units. Using the same VP settings for all 