Monogram ZVC30LSS Instrução De Instalação

Página de 24
Advance Planning
ADVANCE PLANNING
Ductwork Planning
•This hood is equipped for 8
″ round ductwork. 
•Determine the exact location of the vent hood.
•Plan the route for venting exhaust to the outdoors.
This hood is not designed for a recirculating
venting operation.
•Use the shortest and straightest duct route 
possible. For satisfactory performance, duct run
should not exceed 100 ft. equivalent length for any
duct configurations. 
•Refer to “Duct Fittings” chart to compute the 
maximum permissible length for duct runs to 
the outdoors.
•Use rigid metal ductwork only.
•Install a wall or roof cap with damper at the
exterior opening. Order the cap and any transitions
needed in advance.
Wall and Ceiling Framing for Adequate Support
This vent hood is heavy and the cabinet structure
needs to support the weight of the loaded insert
sleeve. Adequate structural support must be
provided in all types of installations. 
•Installation will be easier if the vent hood is
installed before the cooktop is installed.
Custom Cabinet Frame Planning
•The custom-built canopy should be sized to
accommodate the hood insert sleeve. See pages
5–9 for details.
Remote Mounting of the Control (Wired)
•The control can be remotely mounted on the wall
or the countertop.
•It is recommended that you use a professional
installer for the countertop cutout.
•It is recommended that the cutout in a granite
countertop or other hard surface be made before
the countertop is installed.
•The cutout needs to be made at least 6 inches
from the edges of the countertop.
•If mounting in the countertop above a drawer,
consideration must be given to the depth of the
control mounting assembly.
•A 30 ft. wire cord is provided. Careful consideration
must be given to the location of the remotely
mounted control.
•It is recommended that the 4-wire cord be routed
through 1
″ conduit between the insert sleeve and
the remote mounting location.
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
AVERTISSEMENT :
POUR 
DES RAISONS DE SÉCURITÉ, CET APPAREIL
DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with 
this appliance. Follow National electrical codes or
prevailing local codes and ordinances. 
Electrical Supply
This vent hood must be supplied with 120V, 60Hz, 
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp 
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before 
proceeding.
• Route house wiring as close to the installation
location as possible, in the ceiling or back wall.
• Connect the hood wiring to the house wiring in 
accordance with local codes.
• House wiring must extend to 45
″ minimum from
bottom of cabinet in order to make connection to
hood wiring.
Grounding Instructions
The grounding conductor must be connected to 
a grounded metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING:
The improper 
connection of the equipment-grounding 
conductor can result in a risk of electric
shock. Check with a qualified electrician or service
representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT :
Le mauvais branchement du fil de mise 
à la terre peut causer un choc électrique.
En cas de doute, consultez un électricien qualifié 
ou un technicien pour déterminer si l’appareil est 
à la terre.
10