INSTALLATION REQUIREMENTS
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when subjected 
to natural gas, causing gas leaks. Use ONLY black iron, 
stainless steel, or plastic-coated brass piping for gas 
supply.
Gas supply requirements
Electrical requirements for gas dryer
CIRCUIT -  Individual, properly polarized and grounded 
15 amp. branch circuit fused with 15 amp. time delay 
fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt, single 
phase, 60 Hz, Alternating Current. 
POWER SUPPLY CORD - The dryer is equipped with a 120 
volt 3-wire power cord. 
GROUNDING CONNECTION - See “Grounding 
requirements” in Electrical Installation section. 
Grounding type
Grounding type
wa
wall receptacl
ll receptacle
Po
Power cord with
wer cord with
3-prong 
3-prong  gr
grounded plug
ounded plug
Do not,
Do not, under
under
an
any cir
y circumstances,
cumstances,
cut,
cut, remo
remove
ve,
or b
or bypass th
ypass the
gr
grounding pr
ounding prong.
ong.
1  Installation MUST conform with local codes, or in 
the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1 (latest edition). 
2  The gas supply line should be 1/2 inch (1.27 cm) 
pipe. 
3  If codes allow, fl exible metal tubing may be used 
to connect your dryer to the gas supply line. The 
tubing MUST be constructed of stainless steel or 
plastic-coated brass.
  4  The gas supply line MUST have an individual 
shutoff valve installed in accordance with the 
B149.1, Natural Gas and Propane Installation Code.
  5  A 1/8 inch (0.32 cm) N.P.T. plugged tapping, 
accessible for test gauge connection, MUST be 
installed immediately upstream of the gas supply 
connection to the dryer.
  6  The dryer MUST be disconnected from the gas 
supply piping system during any pressure testing 
of the gas supply piping system at test pressures in 
excess of 1/2 psig (3.45 kPa).
  7  The dryer MUST be isolated from the gas supply 
piping system during any pressure testing of the 
gas supply piping system at test pressures equal to 
or less than 1/2 psig (3.45 kPa).
  8  Connections for the gas supply must comply with 
the Standard for Connectors for Gas Appliances, 
ANSI Z21.24.