INSTALLATION REQUIREMENTS
Correct
Incorrect
Correct
Incorrect
Exhaust system requirements
Use only 4 inch (102 mm) diameter (minimum) rigid 
or fl exible metal duct and approved vent hood which 
has a swing-out damper(s) that open when the dryer 
is in operation. When the dryer stops, the dampers 
automatically close to prevent drafts and the entrance 
of insects and rodents. To avoid restricting the outlet, 
maintain a minimum of 12 inches (30.5 cm) clearance 
between the vent hood and the ground or any other 
obstruction.
If your present system is made up of plastic duct or 
metal foil duct, replace it with a rigid or semi-rigid metal 
duct. Also, ensure the present duct is free of any lint prior 
to installing dryer duct.
The following are specifi c requirements for proper 
and safe operation of your dryer.
WARNING
FIRE HAZARD
Failure to follow these instructions can create excessive 
drying times and fi re hazards.
WARNING
FIRE HAZARD
Do not install a clothes dryer with fl exible plastic or 
metal foil venting materials. Flexible venting materials 
are known to collapse, be easily crushed and trap lint. 
These conditions will obstruct clothes dryer airfl ow and 
increase the risk of fi re.