Monogram ZV800SJSS Instrução De Instalação

Página de 24
INSTALLATION BELOW 
A WALL CABINET
Order a cabinet that is at least 20” high from the 
bottom frame to the inside top. The cabinet must be 
at least 12” deep.
• The hood installation height is determined by the
ceiling height.
• The hood installation height must be 24” Min. above
the cooking surface.
7
WALL MOUNT INSTALLATIONS
These hoods may be installed onto a wall or below a
wall cabinet.
• Telescopic duct covers are provided to conceal the
ductwork, running to the ceiling.
• This hood can be installed for recirculating operation.
No kits required.
The vent hood must be installed 24” min. and 30” max.
above the cooking surface. The hood installation
height, from the cooking surface to the bottom 
of the hood, depends upon ceiling height.
Installation Preparation
Wall Mount ZV800 Installation Heights
Actual
*Possible
Celing
*Possible VENTED
RECIRCULATING
Height
Installation Height
Installation Height
7’11”
24” to 27”
24” to 25”
8’ 0”
24” to 28”
24” to 26”
8’ 1”
24” to 30”
24” to 27”
8’ 2” 
24” to 30”
24” to 28”
8’ 3” 
24” to 30”
24” to 29”
8’ 4” 
24” to 30”
24” to 30”
8’ 5” 
24” to 30”
24” to 30”
8’ 6” 
24” to 30”
24” to 30”
8’ 7” 
24” to 30”
24” to 30”
8’ 8” 
24” to 30”
24” to 30”
8’ 9” 
24” to 30”
24” to 30”
8’ 10”
24” to 30”
24” to 30”
8’ 11”
24” to 30”
24” to 30”
9’ 0” 
24” to 30”
24” to 30”
9’ 1”
24” to 30”
24” to 30”
9’ 2”
24” to 30”
24” to 30”
9’ 3”
24” to 30”
24” to 30”
9’ 4”
24” to 30”
24” to 30”
9’ 5”
24” to 30”
24” to 30”
9’ 6”
24” to 30”
24” to 30”
9’ 7”
25” to 30”
24” to 30”
9’ 8”
26” to 30”
24” to 30”
9’ 9”
27” to 30”
24” to 30”
9’ 10”
28” to 30”
24” to 30”
9’ 11”
29” to 30”
25” to 30”
10’
30”
26” to 30”
*Based on 36” countertop height.
36” Min.
24” Min.
30” Max.
INSTALLATION BELOW A CABINET
*The cabinet must measure at least 20” from the bottom
frame to the inside top. The hood housing will occupy the
interior cabinet space.
24” Min.
*20” Min.