Dacor ER30DSCHLPH Instrução De Instalação
7
Planning the Installation
Cabinet Layout
•
Carefully check the location where the range is to be
installed. For best performance, the range should be placed
away from drafts that may be caused by doors, windows and
heating and air conditioning outlets.
•
To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor strongly recommends
installing a range hood. A range hood should project
horizontally a minimum of five (5) inches beyond the face of
the cabinets.
•
All maximum and minimum dimensions and clearances
shown in the diagram below and on page 8 (as
applicable) must be maintained for safe operation.
•
In the freestanding configuration, the range may be installed
flush to the rear wall. For all installations, Dacor highly
recommends installing a non-combustible material on the rear
wall above the range and up to the vent hood or installation
of a backguard. It is not necessary to install non-combustible
materials behind the range below the countertop height.
•
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
Gas and Electrical Service
•
The shaded area shown denotes the location of the gas
inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the
location of the existing utilities may be utilized provided they
do not interfere with the sides or rear of the range. Check
local building codes for permissible gas valve locations.
•
An external manual shut-off valve must be installed between
the gas inlet and the range for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
•
Access to the gas shut-off valve when the unit is installed.
•
Access to the remote circuit breaker panel or fuse box, when
the range is in place.
•
The gas supply piping, gas shut-off valve and the electrical
junction box or receptacle must be located so they do not
interfere with the range when it is installed.
•
The junction box and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Freestanding Cabinet Cutout Dimensions -
Models ER30D and ER30D-C
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Vertical distance from range top panel level.
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
Non-combustible
surface along
back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
1
36 1/2”
(92.7 cm)
max.
13” (33.0 cm)
max.
4
18” (45.7 cm)
min.
3, 4
Suggested
location of
utilities
3
4
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
Cutout tolerances: +1/16” (+1.6 mm), -0
FREESTANDING CUTOUT
DIMENSIONS
F
G
36” (91.4 cm)*
30” (76.2 cm)**
30 1/16” (76.4 cm)*
* Recommended
** Minimum
See following page for self-rimming cutout
dimensions.
WARNING
Do not operate the range without the backguard in place if the
back wall is made of combustible materials. A fire may result.