Dacor DR30DLP Instrução De Instalação

Página de 20
9
Installation Instructions
Connecting the Wiring to the Range
Refer to the product data label (see page 3) for power 
requirements.
There are four possible ways to wire the range:
4-wire conduit
3-wire conduit, where local codes permit
4-wire appliance cord, where local codes permit  
(see page 12)
3-wire appliance cord, where local codes permit 
(see page 12)
The sections below and on the following pages give directions for 
connecting each type of wiring harness.
 WARNING
Do not connect the green appliance wire to the neutral (white) 
supply wire unless local building codes permit.
Connecting Conduit to the Range
Remove the range electrical access cover from the back of 
1. 
the range.
IMPORTANT:
2. 
 If using a 4-wire connection, loosen the 
grounding screw and remove the neutral to ground jumper 
link from the terminal block. Leave the link in place for 3-wire 
connections.
Remove the nut from the conduit strain relief (not included).
3. 
Slide the wires and the end of the strain relief into the hole on 
4. 
the bottom of the range electrical box.
Before connecting the wires, slide the strain relief nut over 
5. 
the wires and thread it onto the conduit strain relief inside the 
box. Tighten into place.
Connect the white wire to the neutral terminal in the box.
6. 
Connect the black wire to the L1 power supply terminal.
7. 
Connect the red wire to the L2 power supply terminal.
8. 
If using a 4-wire connection, connect the green wire to the 
9. 
grounding screw inside the box.
Replace the range electrical access cover.
10. 
L1 terminal
L1 terminal
L2 terminal
L2 terminal
Black wire
Red wire
White wire
Green wire
Red wire
White wire
Black wire
Conduit strain 
relief nut
Conduit strain 
relief nut
Neutral terminal
Neutral terminal
Neutral to ground 
jumper link
Neutral to ground 
jumper link removed
Grounding screw
3-Wire Conduit Connection - 
Where Local Code Permits
4-Wire Conduit 
Connection 
(preferred)
Remove link on  
4-wire installations
Terminal 
block
Bare wire 
connections
Loop and  
spade terminal 
connections