Planning the Installation
 WARNING
IMPORTANT: Observe all governing codes and ordinances 
during planning and installation. Contact your local building 
department for further information.
Electrical Requirements
IMPORTANT: The information below does not apply to units 
installed in Canada. For units installed in Canada, see Electrical 
Requirements - Canada.
It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a licensed electrician. 
The electrical installation, including minimum supply wire size and 
grounding, must be in accordance with the National Electric Code 
ANSI/NFPA 70-1993* (or latest revision) and local codes and 
ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 
1 Batterymarch Park 
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. Refer to the ratings on the product data label (see 
page 3 for location).
Electrical Specifications
Circuit Required
Total Connected Load
240 Vac, 60 Hz., 30 Amp.*
5.7 kW (23.8 Amp.)
* Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
The ratings above are for reference only - refer to the product 
data label for exact specifications.
Consult local building codes for the type and minimum wire 
gauge to use for the power requirements listed on the rating 
label.
The conduit or appliance cord needs to be long enough to 
allow the range to be pulled out from the wall for service, 
while remaining connected. See page 8 for further details.
The wiring to the range must:
Include a strain relief.
Be terminated by tinned leads, closed loop terminals or 
open ended spade lugs with upturned ends.
Where local code permits, a 3 or 4 wire appliance cord may 
be used. The appliance cord must:
Be UL listed type SRD or SRDT.
Be equipped with a NEMA 14-50P 4-wire plug or, where 
local code permits, a NEMA 10-50P 3-wire plug.
Prior to range installation, have a licensed electrician install a 
conduit junction box or electrical receptacle according to the 
type of wiring used.
Electrical Requirements - Canada
It is the owner’s responsibility to ensure that the required 
4-wire electrical outlet is installed by a licensed electrician 
as specified below prior to range installation. The electrical 
outlet installation, including minimum supply wire size and 
grounding, must be in accordance with all governing codes 
and ordinances.
The correct voltage, frequency and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time 
delay fuse. Refer to the ratings on the product data label (see 
page 3 for location).
Electrical Specifications
Circuit Required
Total Connected Load
240 Vac, 60 Hz., 30 Amp. 4-wire
5.7 kW (23.8 Amp.)
* The ratings above are for reference only - refer to the product 
data label for exact specifications.
Ranges equipped for use in Canada come pre-wired with 
a 4-wire, 66 inch (168 cm) long, appliance cord and NEMA 
14-50P plug.
Do not modify the factory wiring. The plug is designed to plug 
directly into a NEMA 14-50R electrical receptacle installed by 
a licensed electrician according to the above specifications.
Gas Supply Requirements
Check your local building codes for the proper method of 
installation. In the absence of local codes, this appliance 
should be installed in accordance with the National Fuel Gas 
Code ANSI Z223.1.
Be certain that the appliance being installed is correct for 
the gas service provided (natural gas or LP gas). Also, if 
operating the range at an altitude above 4000 ft. (1219 m) 
make sure it is equipped for high altitude operation. Refer to 
the product data label and the table on page 3 to determine 
the correct model.
See the table below for gas supply pressure requirements.
The regulator inlet accommodates a 3/4” gas line. The range 
ships with a 1/2” to 3/4” adapter connected to the regulator.
Gas Supply Specifications
Gas 
Type
Manifold 
Pressure* (WC)
Min. Gas Supply 
Pressure (WC)
Max. Input 
Pressure
Natural
5
6
1/2 p.s.i.
LP
10
11
1/2 p.s.i.
The ratings above are for reference only - refer to the product 
data label (see page 3 for location).
NEMA 10-50P Plug
NEMA 14-50P Plug
NEMA 14-50R Receptacle