Planning the Installation
Cabinet Layout
Carefully check the location where the range is to be 
installed. For best performance, the range should be placed 
away from drafts that may be caused by doors, windows and 
heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce 
accumulated smoke in the room, Dacor strongly recommends 
installing a range hood. A range hood should project 
horizontally a minimum of five (5) inches beyond the face of 
the cabinets.
All maximum and minimum dimensions and clearances 
shown in the diagram below must be maintained for safe 
operation.
The range may be installed flush to the rear wall. A non-
combustible rear wall is not mandatory, but Dacor highly 
recommends installing a non-combustible material from the 
countertop level up to the vent hood or installing the optional 
9 inch backguard.
Any openings in the wall behind the appliance or in the floor 
underneath it must be sealed.
Gas and Electrical Service
The shaded area shown below denotes the location of the 
gas inlet and the electrical junction box/receptacle. This 
is the recommended location. For replacement purposes, 
the location of the existing utilities may be utilized provided 
they do not interfere with the sides or rear of the range. 
Check local building codes for permissible utility connection 
locations.
An external manual shut-off valve must be installed between 
the gas inlet and the range for the purpose of turning on or 
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel or fuse box when 
the range is in place.
The gas supply piping, gas shut-off valve and the electrical 
junction box or receptacle must be located so they do not 
interfere with the range when it is installed.
The junction box and gas shut off valve must be located 
so that the range can be pulled out for service while the 
appliance remains connected.
Required Cabinet Dimensions
Note 2
E
F
2
 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
3
 Consult local code for exact location requirements.
1
 Vertical to combustible surface from range grate level; if 
installing an overhead vent hood, also check the hood 
specifications for minimum required clearances. 
Non-combustible 
surface along 
back wall
recommended
10” (25.4 cm) Min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
Min.
1
37 7/8
(96.2 cm)
Max.
13” (33.0 cm)
Max.
4
18” (45.7 cm)
Min.
1, 4
Suggested 
location of 
utilities
 
3
4
 Not applicable for cabinets more than a horizontal 
distance of 10” (25.4 cm) from the edge of the range.
Cutout tolerances: +1/16” (+1.6 mm), -0
E
F
36” (91.4 cm)* 
30” (76.2 cm)**
30 1/16” (76.4 cm)
* Recommended 
** Minimum