Design Information
5
GROUNDING THE APPLIANCE
Please read carefully.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST 
BE PROPERLY GROUNDED.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing
local codes and ordinances. 
This warming drawer must be supplied with 120V, 60Hz, 
and connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker 
or time delay fuse.
• A properly grounded 3-prong receptacle should be located
within reach of the drawers’ 56" long power cord.
• Locate the receptacle in an adjacent cabinet.
– within 42" of the right side or,
– within 16" of the left side or,
– A recessed receptacle may be located on the right 
side of the cutout, 7" from the back of the cabinet. 
In this location, the excess power cord should 
be coiled and taped to the right side of the unit.
• When two warming drawers are installed side to side, 
they can operate from the same receptacle.
Please read carefully.
The power cord of this appliance is equipped with 
a 3-prong (grounding) plug that mates with a standard 
3-prong grounding wall receptacle to minimize the
possibility of electric shock. The customer should 
have the wall receptacle and circuit checked by 
a qualified electrician to make sure the receptacle 
is properly grounded and has the correct polarity.
• Where a standard 2-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the
customer to have it replaced with a properly grounded 
3-prong wall receptacle.
Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
Rating Plate
Recessed
Receptacle 7"
Max. From Rear
on Right Side
Drill 1-1/2" Hole
For Power Cord For
Left or Right Side
Outlet Location