INSTALLATION MANUAL Installation of the Indoor unit 
1. By using  a  level, put the mounting plate in a perfect
    square position vertically and horizontally.
2. Drill  32  mm  deep  holes  in  the wall  to  fix  the 
    plate;
3. Insert the plastic anchors into the hole;
4. Fix the mounting plate by using the provided tapping 
    screws 
5. Check that the mounting plate is correctly fixed;  
50
5mm
Note : Keep  the drain pipe down towards the direction
of  the wall hole, otherwise  leakage may occur.
Before starting installation, decide on the position of the 
indoor and outdoor units, taking into account the minim-
um space  required around the units 
Install the indoor unit in the room to be air conditio-
ning, avoiding  to install in corridors or communal 
areas. 
Install the indoor unit  at  a  height  of  at least 2.5 m 
from the ground. 
To install, proceed as follows: 
1. Decide where to drill the hole in the wall for the pip-
    ing  ( if  necessary )  according to the position of the 
    mounting plate; 
2. Install a flexible flange through the hole in the wall to 
    keep the area intact and clean. 
The hole must slope downwards towards the exterior 
Note : The shape of the mounting plate may be different
 from the  one above, but installation method is similar.
Indoors
Outdoors
1. Lift the front panel.
2. Take  off  the  cover  as  indicated in the picture  ( by 
    removing a screw or by breaking the hooks).
3. For the electrical connections, see the circuit diagram 
    on the right part of the unit under the front panel.
4. Connect  the  cable  wires  to the screw terminals by 
    following  the  numbering, Use wire size suitable to 
    the electric power input (see name plate on the unit) 
    and  according  to  all  current  national  safety  code 
    requirements.
5. The  cable  connecting  the outdoor  and indoor units 
    must be suitable for outdoor use. 
6. The plug must be accessible also after the appliance 
    has been installed so that it can be pulled out if nece-
    ssary.
7. An efficient earth connection must be ensured.
8. If the power cable is damaged, it must be replaced by 
    an authorized Service Centre.   
Front panel
Terminal block cover 
wiring diagram
Note:The cable wires has been connected  to the main 
PCB of  indoor unit  by manufacturer according to the 
model without  terminal block. 
17
Installation of the mounting plate
Drilling a hole in the wall for the piping 
Electrical connections Indoor unit