INSTALLATION MANUAL Installation of the Indoor unit 
INSTALLATION OF THE INDOOR UNIT 
refrigerant 
pipe
refrigerant 
pipe
insulation 
sleeve
          
 connection
(for heat-pump)
 cable 1
connection 
cable
Probe 
cable(for heat-pump)
Condensed water
drain pipe
Covered by vinyl tape 
After having connected the pipe according to the instruc-
tions, install the connection cables. Now install the drain 
pipe. After connection, cover the pipe, cables and drain pipe  
with the insulating material. 
1. Arrange the pipes ,cables and drain hose well.
2. Cover the pipe joints with insulating material,  securing 
    it with vinyl tape. 
3. Run the bound pipe, Cables  and  drain  pipe  through 
    the wall hole and mount the indoor unit onto the upper 
    part of the  mounting plate securely.
4. Press and push the lower part of the indoor unit tightly 
    against the mounting plate
  mounting plate
INSTALLATION MANUAL Installation of the outdoor unit 
 The  outdoor  unit  should be  installed on a solid wall 
     and fastened securely.
 The following procedure must be observed before co-
     nnecting  the  pipes  and  connecting  cables :  decide 
     which is the best position on the wall and leave enough 
     space  to be able to carry out maintenance easily.
 Fasten  the support  to  the  wall using  screw  anchors 
     which are particularly suited to the type of wall;
 Use  a larger quantity of screw anchors than normally  
     required  for  the  weight  they  have  to  bear to aviod 
     vibration during operation and remain fastened  in the 
     same position for years without the screws  becoming 
     loose.
 The  unit  must  be  installed  following  the  national 
     regulations.
drain pipe
The  condensed  water and the ice formed in the outdoor 
unit during heating operation can be drained away thro-
ugh the drain pipe.
1. Fasten the drain port  in the 25mm  hole placed  in the  
    part  of the unit as shown in the picture.
2. Connect  the drain port  and the  drain pipe.
    Pay attention  that  water is drained in a suitable place.
19
Outdoor unit condensed water drainage
(only for heat pump models)
drain port