Frigidaire FHWC3640MS Manual Do Proprietário

Página de 17
11
Vent Connector Installation
Install 7” (17.8 cm) round vent mounting plate or 3¼” x 
10” (8.3 x 25.4 cm) vent connector, depending on your 
vent system installation. Attach to range hood using the 
indicated screws provided in hardware kit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
NOTE
The ” (1.8 cm) round vent mounting plate or 
the 3¼” x 10” (8.3 x 25.4 cm) rectangular vent 
connector can be installed up to 1” (. cm) on 
either side of the hood center to accommodate 
off center ductwork.
If a vent damper is installed with a wall cap with  
  damper, check that they do not interfere with each 
  other. Remove the vent connector damper flap if 
  they interfere. 
 
Power Supply Cable Installation
For direct wire installations, run the home power 
  supply cable according to the National Electric Code 
  or CSA standards and local codes and ordinances. 
  There must be enough wiring from the fused disconnect  
  (or circuit breaker) box to make the connection in the 
  hood electrical terminal box.  
1.
Lift the range hood up under cabinet and determine 
  final location by centering beneath cabinet. Mark on 
  the underside of cabinet the location of the 4 keyhole  
  mounting slots on the range hood (See slot dimensions  
  on page 6). Set range hood aside on a covered surface. 
 
 
 
 
 
 
 
 
 
Use ¹⁄
8
” (3 mm) drill bit and drill 4 pilot holes as shown. 
NOTE: Make the drill holes on the thin area of the slot.  
 
 
 
Install the 4 - .45 cm x 1.3 cm mounting screws in 
  pilot holes. Leave about ¼” (6.4 mm) space between   
  screw heads and cabinet to slide range hood into place. 
 
 
 
For roof installations, remove the top rectangular or    
  round vent knockout depending on which vent system 
  you desire to install. For wall installations, remove the   
  rear rectangular vent knockout. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
.
.
4.
A
A. Keyhole slot
A
¹⁄4”
(6.4 mm)
A
A. Drill pilot hole
A
B
A. Top rectangular knockout
B. Rear rectangular knockout
C. Top round knockout
C
A
C
D
B
C
B
A
A
B
Install the 3¼” x 10” (8.3 x 
25.4 cm) rectangular vent 
transition
A. 3¼” x 10” (8.3 x 25.4 cm)  
    rectangular vent transition
B. .35 x .65 cm screws
C. Rectangular vent knockouts
INSTALLING THE HOOD
Install the 7” (17.8 cm) 
round vent mounting plate
A. .29 x .65 cm screws
B. 7” (17.8 cm) round vent     
    mounting plate.
C. Round vent knockout
D. Rectangular vent knockout