Frigidaire FHWC3640MS Manual Do Proprietário

Página de 17
1
INSTALL RANGE HOOD 
(Recirculating version)
 
Lift the range hood up under cabinet and determine 
  final location by centering beneath cabinet. Mark on 
  the underside of cabinet the location of the 4 keyhole  
  mounting slots on the range hood (See slots  
  dimensions on page 6). Set range hood aside on a  
  covered surface. 
 
 
 
 
 
 
 
 
Use ¹⁄
8
” (3 mm) drill bit and drill 4 pilot holes as shown. 
NOTE: Make the drill holes on the thin area of the slot.  
 
 
 
Install the 4 - .45 cm x 1.3 cm mounting screws in 
  pilot holes. Leave about ¼” (6.4 mm) space between   
  screw heads and cabinet to slide range hood into place. 
 
 
 
Power Supply Cable Installation
For direct wire installations, run the home power 
  supply cable according to the National Electric Code 
  or CSA standards and local codes and ordinances. 
  There must be enough wiring from the fused disconnect  
  (or circuit breaker) box to make the connection in the 
  hood electrical terminal box. 
 
  
NOTE
Do not reconnect power until the installation is 
complete.
 
Remove the screw from the  
  terminal box cover.  
  Remove terminal box cover  
  and set aside. 
 
 
1.
.
.
1.
.
¹⁄4”
(6.4 mm)
A
A. Drill pilot hole
Remove the power supply knockout from the top 
  or rear of the vent hood (depending on the incoming 
  location of your home power supply cable) and  
  install a UL listed or CSA approved ½” strain relief. 
 
 
 
 
 
 
 
 
 
Using 2 or more people, lift the hood into final position. 
  Feed enough electrical wire through the ½” UL listed  
  or CSA approved strain relief to make connections in  
  the terminal box. Tighten the strain relief screws.
Position the range hood so that the large end of 
  the keyhole slots are over the mounting screws. 
  Then push the hood toward the wall so that the screws  
  are in the neck of the slots. Tighten the mounting screws,  
  making sure the screws are in the narrow neck of slots.
Recirculation Vent Cover
For installations which are recirculating the air exhaust, 
the recirculation vent cover must be removed.  
Remove the recirculating  
vent cover by removing  
the 2 mounting screws  
with a phillips screwdriver.   
 
NOTE: For installations  
which are venting out  
the roof or wall, the  
recirculating vent cover  
must remain in place.    
Do not remove as unit  
will not perform properly.
 
 
To complete the installation, go to “Make Electrical  
Connection” section on page 1.
.
4.
.
Part being removed
A
A. Power supply  
     knockout
A. Terminal box cover
B. Screw
A
B
A
A. Keyhole slot
A
INSTALLING THE HOOD