Service manual 
31 
 
3
T-Ts
Room temp. up
Room temp. down
5
High fan
Low fan
1
Mid. fan
 
 
Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. ) 
TE5
T
EVAP. temp. up
EVAP. temp. down
TE6
Compressor and 
outdoor fan on
Compressor and outdoor 
fan off (after 5 mins)
 
 
8.6 
  Dehumidifying mode 
8.6.1  The 4-way valve is off in dehumidifying mode 
8.6.2  Compressor and Indoor Fan actions in dehumidifying mode 
0
TA-TS
2
C
B
A
 
Block
Indoor
Fan
Compressor and Outdoor Fan
LOW
ON  6minutes
BREEZE OFF 4minutes
LOW
ON  5minutes
BREEZE OFF 5minutes
LOW
ON  4minutes
BREEZE OFF 6minutes
A
B
C
 
Repeat on and off cycle. 
8.6.3  Low room temperature protection: 
When room temperature decreases to below 10
, compressor and outdoor fan will stop(indoor fan is 
Breeze). Dehumidifying operation will be resumed when room temperature restores to over 13
8.6.4  At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as