5. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
To prevent damage to the freezer mechanism, do not operate this Ice Maker
when the water supply is OFF, or if the pressure is below 10 PSIG (0.7 bar),
the recommended water pressure.  Stop the Ice Maker until proper water
pressure is resumed.
* Attach the brass fitting included in the accessory bag as shown in Fig. 5.  The brass fitting
size is a 1/2" FPT and must be connected only to a potable water supply.
* A water supply line shut-off valve and drain valve must be installed.
* Water supply pressure should be a minimum of 10 PSIG (0.7 bar) and a maximum of 113
PSIG (7.5 bar).  If the pressure exceeds 113 PSIG (7.5 bar), use a pressure reducing
valve.
* Drain outlet hose is 5/8" (16mm) ID and internally connected with 2/3" (17mm) OD drain
outlet.
* For gravity drain installation, drain must be 1/4" fall per foot (2 cm fall per meter) on horizontal
runs to get good flow.
* Keep a more than 2 vertical inch
   (5 vertical cm) air gap between
   the drain pipe end and the sink.
* The drain pipe must be so laid as to prevent
a backflow into the Storage Bin.
* For condensate pump installation for exiting
drain, refer to condensate pump instruction
manual.
*  A plumbing permit and services of a licensed
plumber may be required in some areas.
* This Ice Maker should be installed in
accordance with applicable national, state
and local regulations.
Fig. 6
Ice Maker
Shut-off Valve
Drain Valve
Water Supply Inlet
3/4" BSP Threads
Bin Drain Outlet
Hose 5/8" ID
1/4" fall per foot
To approved floor drain
Attach brass fitting to
Water Supply Inlet.
Fitting size is a 1/2" FPT