Sanyo KH3072R / CH3072R Manual Do Utilizador

Página de 180
1
2
3
4
5
6
I-4
SM831148
1. Specifications
1-1 Unit Specifications
Wall-Mounted Type
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
Indoor Unit
KH3072R
Outdoor Unit
CH3072R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling
Heating
Capacity * [minimum~muximum] 
BTU / h
29,800 [9,500~29,800]
34,800 [8,000~34,800]
(17˚F)**
BTU / h
20,000
Moisture removal (High) 
Pints / h
9.7
Air circulation (H / M / L) 230 V 
CFM
840 / 740 / 620
External Static Pressure
in. WG
S.E.E.R. / H.S.P.F. (Region 4)
BTU / Wh
15.0
9.0
ELECTRICAL RATINGS
 
Voltage rating
V
230
208
230
208
Available voltage range
V
VAC 187 - 253
VAC 187 - 253
Max. Running amperes*
A
17.7
19.6
16.2
17.9
Power input
W
3,690
3,690
3,390
3,390
(17˚F)**
W
2,460
2,460
Back-up Heater
kW
Maximum overcurrent protection   (Indoor/Outdoor)
A
15 / 35
Low ambient control 
Built-in 0˚F
Fan speeds Indoor / Outdoor
3 and Automatic control / Variable
Optional Wired Remote Controller 
Optional Wireless Remote Controller
RCS-SH1UA  /  RCS-BH80UA. WL  
Air deflection (Horizontal / Vertical )
 / Automatic (Vertical )
Air filter
Washable
Drain pump (Drain connection)
  (20A , OD26mm)
Compressor
Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A
46 / 42 / 38
Outdoor - Hi
dB - A
52
Refrigerant control
Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length
ft. (m)
165 (50)
Limit of tubing length at shipment
ft. (m)
10~100 (3~30)
Limit of elevation difference
ft. (m)
Outdoor unit is higher than indoor unit : 100 (30)
between the two units
ft. (m)
Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube
Narrow tube
in. (mm)
 3 / 8 (6.35)
outer diameter
Wide tube
in. (mm)
 5 / 8 (15.88)
Refrigerant amount at shipment
lbs. (kg) 
5.73 (2.6) - R410A 
DIMENSIONS & WEIGHT
Indoor unit 
Outdoor unit
Unit dimensions
Height
in. (mm)
14- 9/16 (370)
30- 23/32 (780) 
Width
in. (mm)
59- 1/16 (1,500)
37 (940)
Depth
in. (mm)
9- 7/16 (240)
13- 3/8 (340)
Package dimensions
Indoor unit 
Outdoor unit
Height
in. (mm)
18- 7/16 (468)
34- 31/32 (888)
Width
in. (mm)
62- 9/16 (1,589)
39- 31/32 (1,015)
Depth
in. (mm)
12- 9/16 (319)
16- 3/32 (409)
Net weight
lbs. (kg) 
63.9 (29)
143 (65)
Shipping weight
lbs. (kg) 
81.6 (37)
161 (73)
Shipping volume
cu.ft. (m 3 )
8.4 (0.237)
13.0 (0.369)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
Controls
Microprocessor
RCS-SH80UG / RCS-TM80BG