Hitachi L200 Manual Do Utilizador

Página de 280
L200 Inverter
Oper
ations
and Monitor
ing
4–11
The two diagrams below show input wiring circuits using an external supply. If using the 
upper wiring diagram, be sure to use a diode with the external supply. This will prevent a 
power supply contention in case the SR/SK switch is accidentally placed in the incorrect 
position. Be sure to use the correct SR/SK switch position shown for each wiring 
diagram.
L200
L
24V

SK
SR
SK
SR
PCS
Input 
circuits
1
5
Logic GND
1
5
GND
Open collector outputs, 
NPN transistors
Input 
switches
Sinking Inputs, External Supply
SR/SK switch = SK position
Field device
L200
L
24V

SK
SR
SK
SR
PCS
Input 
circuits
1
5
1
5
GND
PNP transistor
sourcing outputs
Input 
switches
Sourcing Inputs, External Supply
SR/SK switch = SR position
Field device
Logic GND
24V


+V
*
*
* Note: If the external power supply GND is (optionally) 
connected to [L], then install the above diode.
24V


24V