C001
Terminal [1] function
R/W
00A7h
0, 1, 2, 3, 
4, 5, 6, 7, 
8, 9, 11, 
12, 13, 
15, 16, 
18, 19, 
20, 21, 
22, 23, 
24, 27, 
28, 29, 
31, 50, 
51, 255
C002
Terminal [2] function
R/W
00A8h
C003
Terminal [3] function
R/W
00A9h
C004
Terminal [4] function
R/W
00AAh
C005
Terminal [5] function
R/W
00ABh
C011
Terminal [1] active state R/W Select logic convention, two 
option codes:
00... normally open [NO]
01... normally closed [NC]
00ADh
0, 1
C012
Terminal [2] active state R/W
00AEh
0, 1
C013
Terminal [3] active state R/W
00AFh
0, 1
C014
Terminal [4] active state R/W
00B0h
0, 1
C015
Terminal [5] active state R/W
00B1h
0, 1
C021
Terminal [11] function
R/W
00B3h
0, 1, 2, 3, 
4, 5, 6, 7, 
8, 9
C022
Terminal [12] function
R/W
00B4h
C026
Alarm relay terminal 
function
R/W
00B5h
C028
[AM] signal selection
R/W Two available functions:
00... Actual motor speed
01... Motor current
00B7h
0, 1
C031
Terminal [11] active 
state
R/W Select logic convention, two 
option codes:
00... normally open (NO)
01... normally closed (NC)
00B8h
0, 1
C032
Terminal [12] active 
state
R/W Select logic convention, two 
option codes:
00... normally open (NO)
01... normally closed (NC)
00B9h
0, 1
C036
Alarm relay active state
R/W Select logic convention, two 
option codes:
00... normally open (NO)
01... normally closed (NC)
00BAh
0, 1
C041
Overload level setting
R/W Sets the overload signal level 
between 0% and 200% (from 0 
to two times the rated current 
of the inverter)
00BBh
0 to 
20000
0.01 %