Hitachi L200 Manual Do Utilizador

Página de 280
Orientation to Inverter Features
In
v
e
rt
er Mounting
and Installation
2–6
Power Wiring Access - First, ensure no 
power source of any kind is connected to the 
inverter. If power has been connected, wait 
five minutes after powerdown and verify the 
Power LED is OFF to proceed. After 
removing the front housing cover, the housing 
partition that covers the power wiring exit will 
be able to slide upward as shown to the right.
Notice the four wire exit slots (on larger 
model inverters) in the housing partition. This 
helps keep the power wiring (to the left) 
separate from signal-level logic or analog 
wiring (to the right).
Remove the housing partition and as shown as 
set it aside in a secure place while wiring. 
Never operate the inverter drive with the parti-
tion removed or the front housing cover 
removed.
The power input and motor 3-phase wiring 
connect to the lower row of terminals. The 
upper row of power terminals connect to 
optional dynamic braking components.
The following sections in this chapter will 
describe the system design and guide you 
through a step-by-step installation process. 
After the section on wiring, this chapter will 
show how to use the front panel keys to 
access functions and edit parameters.
Power and motor
connection terminals