Using the Front Panel Keypad
In
v
e
rt
er Mounting
and Installation
2–24
Keys, Modes, and Parameters
The purpose of the keypad is to provide a way to change 
modes and parameters. The term function applies to both 
monitoring modes and parameters. These are all accessible 
through function codes that are primarily 4-character 
codes. The various functions are separated into related 
groups identifiable by the left-most character, as the table 
shows.
For example, function “A004” is the base frequency setting for the motor, typically 
50 Hz or 60 Hz. To edit the parameter, the inverter must be in Program Mode (PRG LED 
will be ON). You use the front panel keys to first select the function code “A004.” After 
displaying the value for “A004,” use the Up/Down ( 
 or 
 ) keys to edit it.
NOTE: The inverter 7-segment display shows lower case “b” and “d,” meaning the same 
as the upper case letters “B” and “D” used in this manual (for uniformity “A to F”).
 The inverter automatically switches into Monitor 
Mode when you access “D” Group functions. It 
switches into Program Mode when you access 
any other group, because they all have editable 
parameters. Error codes use the “E” Group, and 
appear automatically when a fault event occurs. 
Refer to 
 for error code details.
Function 
Group
Type (Category) of Function
Mode to Access
PRG LED 
Indicator
“D”
Monitoring functions
Monitor
“F”
Main profile parameters
Program
“A”
Standard functions
Program
“B”
Fine tuning functions
Program
“C”
Intelligent terminal functions
Program
“H”
Motor constant functions
Program
“E”
Error codes
1
2
d
0 0 1
RUN
STOP
RESET
FUNC.
STR
HITACHI
POWER
ALARM
RUN
A
Hz
PRG
1
2
1
2
A - - -
RUN
STOP
RESET
FUNC.
STR
HITACHI
POWER
ALARM
RUN
A
Hz
PRG
1
2
A 0 0 4
RUN
STOP
RESET
FUNC.
STR
HITACHI
POWER
ALARM
RUN
A
Hz
PRG
1
2
5 0.0
RUN
STOP
RESET
FUNC.
STR
HITACHI
POWER
ALARM
RUN
A
Hz
PRG
FUNC.
FUNC.
“D” Group
MONITOR
PROGRAM
“A” Group
“B” Group
“C” Group
“F” Group
“H” Group
“D” Group