Hitachi L200 Manual Do Utilizador

Página de 280
“A” Group: Standard Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–26
NOTE: For A095 and A096 (and for 2nd motor settings), if you set a very rapid Acc1 or 
Dec1 time (less than 1.0 second), the inverter may not be able to change rates to Acc2 or 
Dec2 before reaching the target frequency. In that case, the inverter decreases the rate of 
Acc1 or Dec1 in order to achieve the second ramp to the target frequency.
A095 Acc1 to Acc2 frequency 
transition point
Output frequency at which 
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz
0.0
0.0
Hz
ACC CHfr0000.0Hz
A295 Acc1 to Acc2 frequency 
transition point, 2nd 
motor
Output frequency at which 
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz
0.0
0.0
Hz
2ACCCHfr0000.0Hz
A096 Dec1 to Dec2 frequency 
transition point
Output frequency at which 
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz
0.0
0.0
Hz
DEC CHfr0000.0Hz
A296 Dec1 to Dec2 frequency 
transition point, 2nd 
motor
Output frequency at which 
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz
0.0
0.0
Hz
2DECCHfr0000.0Hz
“A” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF 
(EU)
–FU 
(USA)
Units