Vertex Standard FT-950 Manual Do Utilizador

Página de 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
28 
8. Multi Function Meter 
There are five functions multi-meter. The bottom five selections in the list below are 
transmit functions, determined by the selections of the [METER] switch. 
ALC: 
Indicates the relative ALC voltage. 
SWR:  Indicates the Standing Wave Ratio (Forward: Reflected), from 1.0 to 3.0. 
ID: 
Indicates the final amplifier drain current, 0 to 30 ampere. 
VDD:  Indicates the final amplifier drain voltage (nominal value: 13.8 V). 
COMP:  Indicates the speech compressor level, from 0 to 30 dB. 
Advice: The ALC and ID meters can be provided the Peak-hold function via the Menu 
item “009 DISP PKH ALC” and “010 DISP PKH ID”. 
 
9. TUNER 
This indicator appears when the internal Automatic Antenna Tuner is activated. 
 
10. HI-SWR 
This indicator appears if the directional coupler and microprocessor detect an 
abnormally high SWR condition (over 3.0:1) that cannot be resolved by the Automatic 
Antenna Tuner. 
Note: If this indicator appears, check to be sure that you have the correct antenna 
selected on the current operating band. If so, you will need to check the condition of the 
antenna, its coaxial cable, and/or the connectors on the cable so as to locate and correct 
the fault. 
 
11. MIC EQ 
This indicator appears whenever the Three-Band Parametric Microphone Equalizer is 
activated via the Menu. 
 
12. REC 
This indicator appears while the optional Voice Memory Unit is recording your voice 
message, or the Contest Keyer is recording your CW keying. 
 
13. PLAY 
This indicator appears while the optional Voice Memory Unit is playing back the 
recorded your voice message, or the Contest Keyer is playing back the recorded CW 
keying.