Verifying the Package Contents
If any item is missing or damaged, please 
contact your dealer immediately. Do not install a 
damaged or incomplete appliance.
All Ranges
•  Use & Care Manual
•  Anti-tip Bracket
•  Broiler Grill and Pan
•  Oven Racks
Ranges w/ Gas Top Burners & MRES30 Only
•  Ignitor Cleaning Kit
•  Burner Ring Set
•  Grate/Burner Cap Pack
•  Simmer Plate
Electric Ranges Only
•  Razor Blade Scraper
•  Cooktop Cleaning Cream
Gas Supply Requirements
Check your local building codes for the proper 
method of installation. In the absence of local 
codes, this appliance should be installed in 
accordance with the National Fuel Gas Code 
ANSI Z223.1. Be certain that the appliance 
being installed is correct for the gas service 
being provided.
wARNING:
This appliance must be installed 
by a licensed plumber or gas 
fitter when installed within the 
Commonwealth of Massachusetts.
dacor
Model 
Number
dedicated 
electrical
circuit required
Total
connected
load
Gas type
Manifold
pressure
Min. gas
supply
pressure
RSD30
120/240VAC,
60Hz, 30A
5.4kW (23.3A)
Natural
4” water
column
5” water
column
RSD30LP
Liquid Propane
10” water
column
11” water
column
RSE30
120/240VAC,
4-wire, 60Hz, 50A
11.1kW (46.7A)
N/A
N/A
N/A
MRES30
10.3kW (43.7A)
N/A
N/A
N/A
Gas and Electrical Requirements
Electrical Power Supply 
Requirements
It is the owner’s responsibility to ensure that 
the electrical connection of this appliance 
is performed by a qualified electrician. The 
electrical installation, including minimum supply 
wire size and grounding, must be in accordance 
with the National Electric Code ANSI/NFPA 70-
2002* (or latest revision) and local codes and 
ordinances. 
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage 
must be supplied to the appliance from a 
separate, grounded, circuit that is protected by a 
properly sized circuit breaker or time delay fuse. 
Refer to the data plate, and/or the Table above, 
for gas supply requirements.
wARNING:
If the gas or electric service 
provided does not meet the 
product specifications, do not 
proceed with the installation. 
Call the selling dealer, the gas 
supplier, or a licensed electrician.
NOTES:
1.  The power supply must 
be properly polarized. 
Reverse polarity will result in 
continuous sparking of the 
electrodes, even after flame 
ignition.
2.  If there is any doubt as to 
whether the power supply 
is properly polarized or 
grounded, have it checked by 
a qualified electrician.
3.  If the appliance is connected 
to a 120/208 volt power supply, 
preheat times and cavity 
temperature recovery times 
will be increased slightly.
Gas and Electrical Rough-In 
Locations
NOTE:
The shaded areas shown in 
the illustrations, denotes the 
location of the gas stub and the 
electrical junction box/receptacle. 
These are suggested locations. 
For replacement purposes, the 
location of the existing utilities 
may be utilized provided that they 
do not interfere with the sides 
or rear of the range. Verify that 
local building codes will permit 
installing the gas valve behind the 
range.
A manual shut off valve must be installed in the 
gas piping, external to the appliance, for the 
purpose of turning on or shutting off gas to the 
appliance. Plan the location of the range and the 
gas supply to allow access to the valve when 
the unit is installed and in operation. Access to 
the remote circuit breaker panel/fuse box, with 
the range in place and operating, must also be 
allowed for in the installation. Any openings in 
the wall behind the appliance and in the floor 
under the appliance must be sealed. 
Both the gas supply piping and shut-off valve, 
and the electrical junction box/receptacle must 
be located so they do not interfere with the 
range when it is installed and under operation. 
In addition, the junction box must be located 
so the range can be removed for service when 
the conduit supplied with the unit is attached to 
the junction box. Do not lengthen the conduit or 
wiring provided with the range. 
All dimensions shown are based on standard 
American cabinets 36 inches (914mm) high 
at the finished countertop by 24 inches 
(610mm) deep, with a 25 inch (635mm) overall 
countertop depth. When installing the range 
into nonstandard cabinets, minimum clearances 
shown in the diagrams must be maintained.
Carefully check the location where the range is 
to be installed. For best performance, the range 
should be placed away from drafts that may be 
caused by doors, windows and HVAC outlets.
Cabinet and Countertop Preparation
NOTES:
1.  If cabinet storage space is to 
be provided directly above 
the range, the risk of personal 
injury may be reduced by 
installing a ventilating hood 
that projects horizontally a 
minimum of 5 inches (127mm) 
beyond the face of the 
cabinets. 
2.   The range may be installed 
flush to the rear wall. we 
recommend installing a non-
combustible material on the 
rear wall above the range 
and up to the vent hood. It 
is not necessary to install 
non-combustible materials 
behind the range below the 
countertop height.  
3.   The minimum distance from 
the sides of the range above 
the countertop to combustible 
side walls must be at least 6 
inches (152mm).
The above electrical specifications are for reference only. See the range data plate for exact 